4626.1470 LIGHTING INTENSITY. 6-303.11

The light intensity must be:

A.

at least 10 foot-candles (108 lux) at a distance of 30 inches (75 cm) above the floor, in walk-in refrigeration units and dry food storage areas, and in other areas and rooms during periods of cleaning;

B.

at least 20 foot-candles (215 lux):

(1)

at a surface where food is provided for consumer self-service, such as buffets and salad bars, or where fresh produce or packaged foods are sold or offered for consumption;

(2)

inside equipment such as reach-in and under-counter refrigerators; and

(3)

at a distance of 30 inches (75 cm) above the floor in areas used for handwashing, warewashing, and equipment and utensil storage, and in toilet rooms; and

C.

at least 50 foot-candles (540 lux) at a surface where a food employee is working with food or working with utensils or equipment, such as knives, slicers, grinders, or saws where employee safety is a factor.