Minnesota Administrative Rules
1341.1004 A117.1 SECTION 1004, TYPE B UNITS.
Subpart 1.
A117.1 Section 1004.4.2, Changes in level.
A117.1 section 1004.4.2 is amended to read as follows:
1004.4.2 Changes in Level. Changes in level shall comply with section 303.
Exception: Where exterior deck, patio, or balcony surface materials are impervious, the finished exterior impervious surface shall be 2 inches (50 mm) maximum below the floor level of the adjacent interior spaces of the unit.
Subp. 3.
A117.1 Section 1004.11, Toilet and Bathing Facilities.
A117.1 section 1004.11.3.1.3.1, Parallel approach bathtubs, is amended to read as follows:
1004.11.3.1.3.1 Parallel Approach Bathtubs. A clearance 60 inches (1525 mm) minimum in length and 30 inches (760 mm) minimum in width shall be provided in front of bathtubs with a parallel approach. Lavatories complying with section 606 shall be permitted at the control end of the clearance. A lavatory complying with section 1004.11.3.1.1 or a water closet shall be permitted at one end of the bathtub if a clearance 48 inches (1220 mm) minimum in length and 30 inches (760 mm) minimum in width for a parallel approach is provided in front of the bathtub.
History:
32 SR 9; 39 SR 95
Published Electronically:
January 27, 2015
Official Publication of the State of Minnesota
Revisor of Statutes