This part applies to the construction of vertical heat exchangers.
A vertical heat exchanger must not be constructed, or have piping installed or removed below the frost line, until a permit has been issued by the commissioner to the well contractor or limited well/boring contractor licensed to construct vertical heat exchangers.
The well contractor or vertical heat exchanger contractor must submit to the commissioner a vertical heat exchanger permit application on a form provided by the commissioner. The application must be legible and signed by the well contractor or vertical heat exchanger contractor and the property owner or property owner's agent.
A permit application must be completed for each vertical heat exchanger and must include:
the name and address of the owner of the property on which the vertical heat exchanger will be installed;
the township number, range number, section and one quartile, and the property street address if assigned, of the proposed vertical heat exchanger;
a plan diagram showing the location of the vertical heat exchanger borings, property lines, and structures on the property;
the number, diameter, and depth of all bore holes drilled to install the vertical heat exchanger piping;
The vertical heat exchanger must be constructed within 18 months of the date the permit is issued.