4626.0670 VENDING MACHINE DOORS AND OPENINGS. 4-204.123

A.

Vending machine doors and access opening covers to food and container storage spaces must be tight-fitting so that the space along the entire interface between the doors or covers and the cabinet of the machine, if the doors or covers are in a closed position, is no greater than 1/16 inch (1.5 millimeters) by:

(1)

being covered with louvers, screens, or materials that provide an equivalent opening of not greater than 1/16 inch (1.5 millimeters). Screening of 12 or more mesh to 12 mesh to 1 inch (2.5 centimeters) meets this requirement;

(2)

being effectively gasketed;

(3)

having interface surfaces that are at least 1/2-inch (13 millimeters) wide; or

(4)

having jambs or surfaces to form an L-shaped entry path to the interface.

B.

Vending machine service connection openings through an exterior wall of a machine must be closed by sealants, clamps, or grommets so that the openings are no larger than 1/16 inch (1.5 millimeters).