Minnesota Administrative Rules
1323.0553 SECTION 5.5.3, OPAQUE AREAS.
Subpart 1.
ASHRAE 90.1 section 5.5.3.1 Roof insulation.
ASHRAE 90.1 section 5.5.3.1 is amended to read as follows:
5.5.3.1 Roof insulation. All roofs shall comply with the insulation values specified in Tables 5.5-0 through 5.5-8. Skylight curbs, mechanical curbs, and other roof curbs shall be insulated to the level of roofs with insulation entirely above deck or R-10, whichever is less.
Exception: Historical buildings with roof slopes two units vertical in 12 units horizontal (2:12) or less.
(Subsection 5.5.3.1.1 remains unchanged.)
Subp. 2.
ASHRAE 90.1 section 5.5.3.3 Below-grade wall insulation.
ASHRAE 90.1 section 5.5.3.3 is amended to read as follows:
5.5.3.3 Below-grade wall insulation. Below-grade walls shall have a rated R-value of insulation no less than the insulation values specified in Tables 5.5-0 through 5.5-8. Walls shall be insulated on the exterior side of the wall or integral to the wall.
History:
47 SR 983
Published Electronically:
December 7, 2023
Official Publication of the State of Minnesota
Revisor of Statutes