1305.1705 SECTION 1705, REQUIRED VERIFICATION AND INSPECTION.
§
Subpart 1.
IBC Table 1705.3.
IBC Table 1705.3 is amended as follows:
§
A.
Add "Xc" to the "Periodic" column, row "7. Inspection of concrete and shotcrete placement for proper application techniques."
§
B.
Add footnote "c." to read as follows:
c. Exception: Periodic verification and inspection is permitted, upon approval of the structural engineer of record and the building official.
§
Subp. 2.
IBC section 1705.4.
IBC section 1705.4 is amended by adding the following sentence to the end of the section: "Periodic verification and inspection of grout placement is permitted, upon approval of the structural engineer of record and the building official."