1305.1705 SECTION 1705, REQUIRED VERIFICATION AND INSPECTION.

Subpart 1.

IBC Table 1705.3.

IBC Table 1705.3 is amended as follows:

A.

Add "Xc" to the "Periodic" column, row "7. Inspection of concrete and shotcrete placement for proper application techniques."

B.

Add footnote "c." to read as follows:

c. Exception: Periodic verification and inspection is permitted, upon approval of the structural engineer of record and the building official.

Subp. 2.

IBC section 1705.4.

IBC section 1705.4 is amended by adding the following sentence to the end of the section: "Periodic verification and inspection of grout placement is permitted, upon approval of the structural engineer of record and the building official."