1303.2320 WINDOW FALL PREVENTION REQUIRED.

Windows that are required to comply with part 1303.2310 must be equipped with window fall prevention screens, guards, or other devices that comply with ASTM F 2006 or ASTM F 2090.

Exceptions:

1. Fixed, nonoperable windows.

2. Windows located in basements.

3. Windows located below the first story above grade plane.

4. Windows in which the opening of a window in any position does not permit a four-inch diameter sphere to pass through the opening.

5. Windows in which the bottom of the sill is more than 24 inches (610 mm) above the finished floor.

Statutory Authority:

MS s 326B.02; 326B.101; 326B.106; 326B.13