7011.0735 TABLE 2.

Source Gas Volume, DSCFMa Concentration GR/DSCFb
7,000
or less
0.100
8,000 0.096
9,000 0.092
10,000 0.089
20,000 0.071
30,000 0.062
40,000 0.057
50,000 0.053
60,000 0.050
80,000 0.045
100,000 0.042
120,000 0.040
140,000 0.038
160,000 0.036
180,000 0.035
200,000 0.034
300,000 0.030
400,000 0.027
500,000 0.025
600,000 0.024
800,000 0.021
1,000,000
or more
0.020

Interpolation of the data in this part for airflow rates between 7,000 dscfm and 1,000,000 dscfm must use the equation:

c = 1.7627 x FRcorrected-0.3241

where:

c = concentration limit in gr/dscf

FRcorrected = gas volume in dscfm

aDry standard cubic feet per minute

bGrains per dry standard cubic foot.