7011.0080 MONITORING AND RECORD KEEPING FOR LISTED CONTROL EQUIPMENT.

The owner or operator of a stationary source must comply with the monitoring and record keeping required for listed control equipment by the table in this part. The owner or operator shall maintain the records required by this part for a minimum of five years from the date the record was made. Unless a specific format is required, the records may be maintained in either electronic or paper format. For certified hoods, the owner or operator shall comply with part 7011.0072.

Identification Number(s) Pollution Control Equipment Type Monitoring Parameter(s) Record-keeping Requirement

A.

Equipment designed for particulate matter control

007, 008, 009, 076, Centrifugal collector (cyclone) Pressure drop Record pressure drop every 24 hours if in operation
010, 011, 012, 146 Electrostatic precipitator Voltage, secondary current, and, if used, conditioning agent flow rate Continuous readout of voltage, and secondary current. If used, daily record of conditioning agent flow rate
016, 017 Fabric filter (bag house), high temperature (T>250°F), medium temperature (180°F> T<250°F) Pressure drop Record pressure drop every 24 hours if in operation
018 Fabric filter (bag house), low temperature (T<180°F) Pressure drop or visible emissions observation from filter outlet during an entire cleaning cycle, unless the commissioner specifies pressure drop and/or visible emissions as the indicator(s) of fabric filter performance Record pressure drop every 24 hours if in operation, or Record whether any visible emissions are observed and the time period of observation every 24 hours if in operation; or record both if the commissioner requires monitoring of both parameters
052 Spray tower Liquid flow rate and pressure drop Record each parameter every 24 hours if in operation
053, 055 Venturi scrubber, impingement plate scrubber Pressure drop and liquid flow rate Record each parameter every 24 hours if in operation
056, 113 Mechanically aided separator Pressure drop Record every 24 hours if in operation
058, 101 HEPA and other wall filters Condition of the filters, including, but not limited to, alignment, saturation, and tears and holes Record of filter(s) condition every 24 hours if in operation
057, 085 Wet cyclone separator Pressure drop; and water pressure Record each parameter every 24 hours if in operation
503 Charged scrubber Pressure drop and liquid flow rate Record each parameter every 24 hours if in operation
517 Condensation scrubber Pressure drop and either steam supply rate or blowdown rate Record each parameter every 24 hours if in operation

B.

Equipment designed for volatile organic compound control

021, 022, 131, 133 Thermal afterburner Combustion temperature or inlet and outlet temperatures Record temperatures at least once every 15 minutes
019, 020, 109 Catalytic afterburner Inlet and outlet temperatures; and catalyst bed reactivity as per manufacturer's specifications Record temperatures or manual readings at least once every 15 minutes; and record results of catalyst bed reactivity
023 Flaring Temperature indicating presence of a flame Record temperatures at least once every 15 minutes