Minnesota Administrative Rules
4731.6240 ENTERING AND LEAVING THE RADIATION ROOM.
Subpart 1.
Entry.
Upon first entering the radiation room of a panoramic irradiator after an irradiation, the irradiator operator must use a survey meter to determine that the source has returned to its fully shielded position. The operator must check the functioning of the survey meter with a radiation check source before entry.
Subp. 2.
Exit.
Before exiting from and locking the door to the radiation room of a panoramic irradiator prior to a planned irradiation, the irradiator operator must:
B.
activate a control in the radiation room that permits the sources to be moved from the shielded position only if the door to the radiation room is locked within a preset time after setting the control.
Subp. 3.
Entry during power failure.
During a power failure, the area around the pool of an underwater irradiator may not be entered without using an operable and calibrated radiation survey meter, unless the over-the-pool monitor required under part 4731.6090, subpart 2, is operating with backup power.
History:
29 SR 755
Published Electronically:
March 12, 2009
Official Publication of the State of Minnesota
Revisor of Statutes