4731.6130 POWER FAILURES.

A.

If electrical power at a panoramic irradiator is lost for longer than ten seconds, the sources must automatically return to the shielded position.

B.

The lock on the door of the radiation room of a panoramic irradiator may not be deactivated by a power failure.

C.

During a power failure, the area of any irradiator where sources are located may be entered only when using an operable and calibrated radiation survey meter.