4717.2560 RECIRCULATION RATE.
Subpart 1.
General recirculation rate.
The water recirculation system must clarify and disinfect the pool volume of water in six hours or less.
Subp. 2.
Wading pools and special purpose pools.
The water recirculation system of a wading pool or a special purpose pool must recirculate a water volume equal to the pool volume in two hours or less.
Subp. 3.
Spa pools.
The recirculation system in a spa pool must recirculate a water volume equal to the pool volume in 30 minutes or less, except that a minimum rate of 35 gallons per minute is required.
Subp. 4.
Dedicated plunge pools.
The recirculation system of a dedicated plunge pool must recirculate a water volume equal to the total volume of the pool in one hour or less.