Skip to main content Skip to office menu Skip to footer
Capital IconMinnesota Legislature

Office of the Revisor of Statutes

4714.0313 HANGERS AND SUPPORTS.

Subpart 1.

Section 313.

Table 313.3 is amended to read as follows:

TABLE 313.3
HANGERS AND SUPPORTS
MATERIALS TYPES OF JOINTS HORIZONTAL VERTICAL
Cast Lead and Oakum 5 feet, except 10 feet where 10 foot lengths are installed1,2,3 Base and each floor, not to exceed 15 feet
Compression Gasket Every other joint, unless over 4 feet then support each joint1,2,3 Base and each floor, not to exceed 15 feet
Cast-Iron Hubless Shielded Coupling Every other joint, unless over 4 feet then support each joint1,2,3,4 Base and each floor, not to exceed 15 feet
Copper & Copper Alloys Soldered, Brazed, Threaded, or Mechanical 1-1/2 inches and smaller, 6 feet; 2 inches and larger, 10 feet Each floor, not to exceed 10 feet5
Steel Pipe for Water or DWV Threaded or Welded 3/4 inch and smaller, 10 feet; 1 inch and larger, 12 feet Every other floor, not to exceed 25 feet5
Steel Pipe for Gas Threaded or Welded 1/2 inch, 6 feet; 3/4 inch and 1 inch, 8 feet; 1-1/4 inches and larger, 10 feet 1/2 inch, 6 feet; 3/4 inch and 1 inch, 8 feet; 1-1/4 inches every floor level
Schedule 40 PVC and ABS DWV Solvent Cemented All sizes, 4 feet; allow for expansion every 30 feet3,6 Base and each floor; provide mid-story guides; provide for expansion every 30 feet6
CPVC Solvent Cemented 1 inch and smaller, 3 feet; 1-1/4 inches and larger, 4 feet Base and each floor; provide mid-story guides
CPVC-AL-CPVC Solvent Cemented 1/2 inch, 5 feet; 3/4 inch, 65 inches; 1 inch, 6 feet Base and each floor; provide mid-story guides
Lead Wiped or Burned Continuous Support Not to exceed 4 feet
Steel Mechanical In accordance with standards acceptable to the Authority Having Jurisdiction
PEX Cold Expansion, Insert, and Compression 1 inch and smaller, 32 inches; 1-1/4 inches and larger, 4 feet Base and each floor; provide mid-story guides
PEX-AL-PEX Metal Insert and Metal Compression 1/2 inch; 3/4 inch; 1 inch
All sizes 98 inches
Base and each floor; provide mid-story guides
PE-AL-PE Metal Insert and Metal Compression 1/2 inch; 3/4 inch; 1 inch
All sizes 98 inches
Base and each floor; provide mid-story guides
PE-RT Insert and Compression 1 inch and smaller, 32 inches; 1-1/4 inches and larger, 4 feet Base and each floor; provide mid-story guides
Polypropylene (PP) Fusion Weld (socket, butt, saddle, electrofusion), Threaded (metal threads only), or Mechanical 1 inch and smaller, 32 inches; 1-1/4 inches and larger, 4 feet Base and each floor; provide mid-story guides

For SI units: 1 inch = 25.4 mm, 1 foot = 304.8 mm

Notes:

1 Support adjacent to joint, not to exceed 18 inches (457 mm).

2 Brace not to exceed 40-foot (12,192 mm) intervals to prevent horizontal movement.

3 Support at each horizontal branch connection.

4 Hangers shall not be placed on the coupling.

5 Vertical water lines shall be permitted to be supported in accordance with recognized engineering principles with regard to expansions and contraction, where first approved by the Authority Having Jurisdiction.

6 For expansion joints, see Table 313.3.1.

Subp. 2.

Section 313.

Table 313.3.1 is added to read as follows:

TABLE 313.3.1

Schedule 40 PVC and ABS DWV and Storm Pipe Expansion Table

Inside the building thermal envelope

Length of Run (ft.)

101

201

30

Pipe Size

Expansion joint length (in.) = L

1.5"

20

28

34

2"

22

31

38

3"

27

38

46

4"

30

43

52

6"

37

52

63

8"

42

59

72

10"

47

66

80

12"

51

72

88

Outside the building thermal envelope

Length of Run (ft.)

101

201

30

Pipe Size

Expansion joint length (in.) = L

1.5"

26

36

44

2"

29

41

50

3"

35

49

60

4"

40

56

68

6"

48

68

83

8"

55

77

94

10"

61

86

105

12"

66

94

114

1 Multiple offsets shall be allowed to provide expansion for each 30-foot developed length of run.

Subp. 3.

Section 313.7.

UPC section 313.7 is deleted in its entirety.

Statutory Authority:

MS s 326B.43; 326B.435

History:

40 SR 71; 45 SR 1007

Published Electronically:

September 27, 2021

Official Publication of the State of Minnesota