A radon measurement professional and a radon mitigation professional must:
operate according to a quality assurance and quality control plan submitted to the commissioner under parts 4620.7200 and 4620.7300;
notify the commissioner in writing within 30 days of any change to the license application information provided under parts 4620.7200 and 4620.7300;
maintain proof of a valid license issued under this chapter at all times while at a project site;
use the services of a radon laboratory licensed by the commissioner under part 4620.7350 to analyze radon samples;
maintain radon measurement device calibration records for three years. Device calibration records include the:
not interfere with the commissioner's inspection or audit of any radon measurement or mitigation project.
A radon mitigation company and a radon professional engaged as a sole proprietor with no employees and no subcontractors who are licensed radon mitigation professionals must:
verify that employees directly involved in radon mitigation complete an NRPP-approved training course or a minimum of eight hours of basic mitigation training provided by a licensed radon mitigation professional. The training must be:
documented by having trainees acknowledge with their written signature that they have received training meeting the requirements of this part;
verify that all of its mitigation professionals, employees, and subcontractors comply with parts 4620.7000 to 4620.7950;
verify that radon mitigation is performed with on-site supervision of a licensed mitigation professional;
maintain records for three years of each radon mitigation performed, including records required under parts 4620.7500 and 4620.7600, subpart 2;
notify the commissioner in writing within 30 days of any change to the license application information provided under part 4620.7250; and
obtain a permit from the local unit of government when the installation of a radon mitigation system alters any structural component of the building framing system. A permit is not required when only the rim joist area is penetrated.
An approved radon analysis laboratory must:
notify the commissioner in writing within 30 days of any change to the license application information provided under part 4620.7350; and
maintain the status requirement of part 4620.7350, subpart 2, item H. If status is no longer current, the commissioner shall suspend the radon laboratory license under Minnesota Statutes, section 144.99, subdivision 9.