Except as otherwise provided in part 7045.0526, subpart 1, if the applicant proposes to store containers of hazardous waste, the applicant shall furnish the following information in addition to the information required by part 7001.0560:
A description of the proposed area where the containers will be stored demonstrating that the area complies with part 7045.0526, subpart 6. At a minimum, the description must include:
the manner in which the design promotes drainage or prevents contact between hazardous waste containers and standing liquids;
the capacity of the containment system in terms of the number and volume of containers to be stored;
the manner in which accumulated liquids can be removed to prevent overflow and can be analyzed to determine proper management of the removed liquids.
Information on the type of containers to be used and waste types stored in each type of container, including information on size, capacity, construction material of containers, compatibility of waste with the container, and the number and volume of containers to be stored.
An operations manual that describes operational and maintenance procedures to be used at the facility to ensure proper management of hazardous waste containers.
For storage areas for containers holding wastes that do not contain free liquids, a demonstration of compliance with part 7045.0526, subpart 6, item D, including:
test procedures and results or other documentation or information to show that the wastes do not contain free liquids, and
a description of how the storage area is designed or operated to drain and remove liquids or how contact between containers and standing liquids is prevented.
For any ignitable, reactive, or incompatible wastes, sketches, drawings, or data that demonstrate compliance with part 7045.0526, subparts 7 and 8, if applicable.
MS s 116.07
8 SR 2276; 33 SR 2042
July 13, 2009
Official Publication of the State of Minnesota