2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 2.27 2.28 2.29 2.30 2.31 2.32 2.33 2.34 2.35 3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22 3.23 3.24 3.25 3.26 3.27 3.28 3.29 3.30 3.31 3.32 3.33 3.34 3.35 3.36
4.1 4.2 4.3 4.4 4.5 4.6 4.7

A bill for an act
relating to high pressure piping; classifying data relating to bioprocess piping
and equipment as nonpublic; including bioprocess piping in the definition of
high pressure piping; amending Minnesota Statutes 2004, sections 16B.61,
subdivisions 2, 3; 326.461, subdivision 2; proposing coding for new law in
Minnesota Statutes, chapter 13.

BE IT ENACTED BY THE LEGISLATURE OF THE STATE OF MINNESOTA:

Section 1.

new text begin [13.7911] BIOPROCESS PIPING AND EQUIPMENT DATA.
new text end

new text begin All data regarding the material production processes, including the bioprocess
system's structural design and layout, are classified as nonpublic data. Bioprocess piping
and equipment are limited to those used in the creation of a product utilizing living
organisms and meeting the most current requirements in the bioprocessing equipment
standard adopted by the American Society of Mechanical Engineers.
new text end

Sec. 2.

Minnesota Statutes 2004, section 16B.61, subdivision 2, is amended to read:


Subd. 2.

Enforcement by certain bodies.

Under the direction and supervision of
the commissioner, the provisions of the code relating to electrical installations shall be
enforced by the State Board of Electricity, pursuant to the Minnesota Electrical Act, the
provisions relating to plumbing shall be enforced by the commissioner of health, the
provisions relating to high pressure steam piping and appurtenancesnew text begin , ammonia piping, and
bioprocess piping
new text end shall be enforced by the Department of Labor and Industry. Fees for
inspections conducted by the State Board of Electricity shall be paid in accordance with
the rules of the State Board of Electricity. Under direction of the commissioner of public
safety, the state fire marshal shall enforce the Minnesota Uniform Fire Code as provided
in chapter 299F. The commissioner, in consultation with the commissioner of labor and
industry, shall adopt amendments to the mechanical code portion of the State Building
Code to implement standards for process piping.

Sec. 3.

Minnesota Statutes 2004, section 16B.61, subdivision 3, is amended to read:


Subd. 3.

Special requirements.

(a) Space for commuter vans. The code must
require that any parking ramp or other parking facility constructed in accordance with the
code include an appropriate number of spaces suitable for the parking of motor vehicles
having a capacity of seven to 16 persons and which are principally used to provide
prearranged commuter transportation of employees to or from their place of employment
or to or from a transit stop authorized by a local transit authority.

(b) Smoke detection devices. The code must require that all dwellings, lodging
houses, apartment houses, and hotels as defined in section 299F.362 comply with the
provisions of section 299F.362.

(c) Doors in nursing homes and hospitals. The State Building Code may not
require that each door entering a sleeping or patient's room from a corridor in a nursing
home or hospital with an approved complete standard automatic fire extinguishing system
be constructed or maintained as self-closing or automatically closing.

(d) Child care facilities in churches; ground level exit. A licensed day care center
serving fewer than 30 preschool age persons and which is located in a belowground space
in a church building is exempt from the State Building Code requirement for a ground
level exit when the center has more than two stairways to the ground level and its exit.

(e) Child care facilities in churches; vertical access. Until August 1, 1996, an
organization providing child care in an existing church building which is exempt from
taxation under section 272.02, subdivision 6, shall have five years from the date of initial
licensure under chapter 245A to provide interior vertical access, such as an elevator, to
persons with disabilities as required by the State Building Code. To obtain the extension,
the organization providing child care must secure a $2,500 performance bond with the
commissioner of human services to ensure that interior vertical access is achieved by the
agreed upon date.

(f) Family and group family day care. Until the legislature enacts legislation
specifying appropriate standards, the definition of Group R-3 occupancies in the State
Building Code applies to family and group family day care homes licensed by the
Department of Human Services under Minnesota Rules, chapter 9502.

(g) Enclosed stairways. No provision of the code or any appendix chapter of the
code may require stairways of existing multiple dwelling buildings of two stories or
less to be enclosed.

(h) Double cylinder dead bolt locks. No provision of the code or appendix chapter
of the code may prohibit double cylinder dead bolt locks in existing single-family homes,
townhouses, and first floor duplexes used exclusively as a residential dwelling. Any
recommendation or promotion of double cylinder dead bolt locks must include a warning
about their potential fire danger and procedures to minimize the danger.

(i) Relocated residential buildings. A residential building relocated within or
into a political subdivision of the state need not comply with the State Energy Code or
section 326.371 provided that, where available, an energy audit is conducted on the
relocated building.

(j) Automatic garage door opening systems. The code must require all residential
buildings as defined in section 325F.82 to comply with the provisions of sections 325F.82
and 325F.83.

(k) Exit sign illumination. For a new building on which construction is begun
on or after October 1, 1993, or an existing building on which remodeling affecting 50
percent or more of the enclosed space is begun on or after October 1, 1993, the code must
prohibit the use of internally illuminated exit signs whose electrical consumption during
nonemergency operation exceeds 20 watts of resistive power. All other requirements in
the code for exit signs must be complied with.

(l) Exterior wood decks, patios, and balconies. The code must permit the decking
surface and upper portions of exterior wood decks, patios, and balconies to be constructed
of (1) heartwood from species of wood having natural resistance to decay or termites,
including redwood and cedars, (2) grades of lumber which contain sapwood from species
of wood having natural resistance to decay or termites, including redwood and cedars, or
(3) treated wood. The species and grades of wood products used to construct the decking
surface and upper portions of exterior decks, patios, and balconies must be made available
to the building official on request before final construction approval.

new text begin (m) Bioprocess piping and equipment. All data regarding the material production
processes, including the bioprocess system's structural design and layout, are trade secret
information under section 13.37 and nonpublic data under section 13.7911. Bioprocess
piping and equipment are limited to those used in the creation of a product utilizing living
organisms and meeting the most current requirements set forth in the bioprocessing
equipment standards adopted by the American Society of Mechanical Engineers. No
permit fee for bioprocess piping may be imposed by municipalities under the State
Building Code, except as required under section 326.47, subdivision 1. Permits for
bioprocess piping shall be according to section 326.47 administered by the Department of
Labor and Industry.
new text end

Sec. 4.

Minnesota Statutes 2004, section 326.461, subdivision 2, is amended to read:


Subd. 2.

High pressure piping.

"High pressure piping" means all high pressure
piping used in the installation of hot water or steam heating boilers, any systems of piping
hot water or other medium used for heating that exceed 30 p.s.i. gauge and 250 degrees
Fahrenheit, or any system of high pressure steam deleted text begin ordeleted text end new text begin ,new text end ammonia piping,new text begin or bioprocess
piping,
new text end but shall not include any high pressure piping under the direct jurisdiction of